E4 is displayed and the unit stops cooling or heating; may restart after some time.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Isolate power before working near the outdoor fan or coil.
Steps:
- Clean outdoor coil: Remove leaves, plastic bags, and dirt from the Bosch outdoor condenser. Use a soft brush and low-pressure water spray from inside out if accessible. Do not bend fins.
- Check outdoor fan: Restore power and observe the outdoor fan when the unit calls for cooling. If the compressor runs but the fan does not, or runs very slowly, the fan motor or its capacitor may be faulty.
- Ensure ventilation: Confirm that there is adequate clearance around the outdoor unit as per Bosch installation manual (typically at least 30–50 cm on sides and more at the front). Remove obstructions.
If E4 persists: Overcharge, blocked refrigerant circuit, or a faulty high-pressure sensor/switch may be present. These require a licensed technician to measure pressures, adjust charge, and test/replace the high-pressure protection device.
Repair Difficulty
Required Part
We may earn a commission from links on this page.