Bryant High Inrush Current / Electrical Supply Issue

Bryant air conditioner causes lights to dim significantly when starting; occasional breaker trips on startup.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak compressor start, Failing start capacitor or hard-start kit, Undersized electrical service, Loose electrical connections

How to Fix / Troubleshooting

Safety first: Turn off power at the main panel and outdoor disconnect before inspecting wiring. High-voltage work should be done by qualified persons.

Steps:

  • 1. Check breaker size: Verify that the breaker size matches the Bryant unit's nameplate MCA/MOP ratings. Do not upsize the breaker beyond manufacturer specs.
  • 2. Inspect connections: With power off, check that lugs in the outdoor disconnect and at the condenser contactor are tight and free of corrosion.
  • 3. Evaluate start components: Many Bryant units use a dual run capacitor and sometimes a start assist kit. A technician can test and replace these to reduce inrush current.
  • 4. Electrical service check: If dimming is severe, have an electrician evaluate the home's service capacity and connections.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Hard Start Kit
Check Price on Amazon

We may earn a commission from links on this page.