Bryant Low-Voltage Power Interruption

Bryant air conditioner occasionally shuts off and thermostat goes blank, then comes back after a short time.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose 24V transformer connections, Intermittent short in thermostat wiring, Failing Bryant control board, Overheating transformer

How to Fix / Troubleshooting

Safety first: Turn off power to the indoor unit before accessing the control compartment.

Steps:

  • 1. Inspect thermostat wiring: At the furnace/air handler and thermostat, ensure all low-voltage wires are firmly attached and not shorting against metal.
  • 2. Check transformer connections: Verify that the 24V transformer primary and secondary connections on the Bryant control board are tight.
  • 3. Look for shorts: Inspect the cable to the outdoor unit for damage from lawn equipment or animals. Repair any nicks or cuts.
  • 4. Monitor operation: If the thermostat continues to drop out, the transformer or control board may be failing and should be tested/replaced by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

24V Transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements