Possible Causes
Repeated high- or low-pressure switch trips, Compressor overcurrent events, Control board internal fault, Persistent communication errors
How to Fix / Troubleshooting
Safety first: Turn off power to the outdoor unit at the disconnect and indoor unit at the breaker.
Steps:
- 1. Review fault history: On Evolution/Preferred thermostats, access the service menu to view detailed fault history. Note which specific faults (e.g., high pressure, low pressure, fan fault) caused the lockout.
- 2. Address root cause: If previous codes indicate airflow issues (dirty coil, fan fault), correct those first (clean coils, check fan motor and capacitor). If low-pressure faults are logged, check filters and airflow and then call a professional for refrigerant diagnostics.
- 3. Clear lockout: After correcting obvious issues, restore power and clear the lockout via the thermostat or by cycling power for 60 seconds.
- 4. Monitor operation: Run the system through a full cooling cycle. If lockout recurs, do not continue resetting; this indicates a serious underlying problem.
Professional help: Repeated lockouts can damage the compressor. Have a Bryant-certified technician perform a full diagnostic, including pressure readings and electrical tests.