Camry
Indoor Fan Motor or Control Failure
Camry air conditioner indoor fan does not run, but compressor and outdoor fan are operating
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed indoor fan motor on Camry wall unit, Faulty fan capacitor (for AC motors), Loose fan motor connector on indoor PCB, Defective indoor PCB fan drive circuit
How to Fix / Troubleshooting
Safety first: Turn off power and wait for all fans to stop before opening the indoor unit.
- 1. Check fan mode: Ensure the fan is not set to OFF or a special mode that stops the fan.
- 2. Inspect wiring: Confirm that the fan motor connector is firmly plugged into the indoor PCB.
- 3. Test motor rotation: Gently spin the blower wheel by hand; if stiff, the motor may be seized.
- 4. Capacitor check: On non-inverter models, test the fan capacitor and replace if out of tolerance.
- 5. Replace motor or PCB: If the motor does not receive voltage or is electrically open, replace the motor; if voltage is present but motor does not run, the motor is faulty.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Indoor Fan Motor (Camry Wall Split)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements