F5
Camry Mode Control / Four-Way Valve Fault

F5 error; unit may not switch modes correctly or may shut down

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck four-way reversing valve on Camry heat pump, Faulty four-way valve coil, Incorrect wiring to valve coil from outdoor PCB, Defective outdoor PCB output to valve

How to Fix / Troubleshooting

Safety first: Turn off power and do not attempt to open the refrigerant circuit.

  • 1. Listen for valve shift: When switching between COOL and HEAT, you should hear a distinct click from the four-way valve. Absence of this sound may indicate a coil or valve issue.
  • 2. Check coil wiring: Inspect the two wires leading to the four-way valve coil for secure connections and no damage.
  • 3. Measure coil resistance: With power off, measure the coil resistance and compare with Camry specifications. Replace the coil if open or shorted.
  • 4. PCB output check: A technician can verify that the outdoor PCB is supplying the correct voltage to the coil when changing modes.
  • 5. Valve mechanical fault: If the coil is good and powered but the valve does not shift, the valve body may be stuck and require replacement by a refrigeration technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Four-Way Reversing Valve Coil (Camry Heat Pump)
Check Price on Amazon

We may earn a commission from links on this page.