H2
Camry
Compressor Overheat Protection
H2 error; compressor stops and unit may not restart until cooled
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked outdoor coil on Camry condenser, Outdoor fan failure, Low refrigerant charge causing overheating, Faulty compressor thermal protector
How to Fix / Troubleshooting
Safety first: Turn off power and allow the outdoor unit to cool completely.
- 1. Clean outdoor coil: As described for E3, ensure the coil is clean and unobstructed.
- 2. Verify fan operation: Confirm that the outdoor fan starts and runs at full speed whenever the compressor is running.
- 3. Check ambient conditions: In extremely high outdoor temperatures, reduce indoor load (raise setpoint) to reduce compressor stress.
- 4. Professional checks: A technician should verify refrigerant charge and inspect the compressor thermal protector and windings.
- 5. Avoid repeated resets: Do not repeatedly restart the unit after H2; this can permanently damage the compressor.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Outdoor Fan Motor (Camry Condenser Unit)
Check Price on Amazon
We may earn a commission from links on this page.