H3
Camry
Compressor Overload / IPM Protection
H3 displayed; unit shuts down and will not restart until power is cycled
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Inverter module overheating on Camry outdoor PCB, Shorted compressor windings, Poor ventilation around outdoor unit, Faulty IPM (Intelligent Power Module)
How to Fix / Troubleshooting
Safety first: Isolate power and wait for at least 10 minutes before touching the outdoor PCB or compressor area.
- 1. Check ventilation: Ensure the outdoor unit has adequate clearance and is not installed in a confined space trapping hot air.
- 2. Inspect PCB heat sink: Look for dust buildup on the inverter heat sink and clean gently if accessible.
- 3. Measure compressor current (technician): Excessive current draw indicates compressor or refrigerant issues.
- 4. Test compressor windings: As with E5, check for shorts or imbalance.
- 5. Replace IPM/PCB if needed: If the compressor is healthy but H3 persists, the inverter module or entire outdoor PCB may need replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Outdoor Inverter PCB (Camry Condenser Unit)
Check Price on Amazon