P0
Camry Inverter Module Protection / DC Bus Voltage Error

P0 displayed; compressor does not start or runs at very low speed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Abnormal DC bus voltage on Camry inverter board, Faulty PFC (power factor correction) circuit, Loose DC bus connectors, Defective inverter PCB

How to Fix / Troubleshooting

Safety first: High DC voltages are present on the inverter; only trained personnel should measure or service this area.

  • 1. Power reset: Turn off power for at least 15 minutes to allow DC capacitors to discharge, then restore power and test.
  • 2. Inspect PCB: Look for swollen capacitors or burnt components in the DC bus area.
  • 3. Check connectors: Ensure all plug-in connectors between rectifier, PFC, and IPM sections are secure.
  • 4. Measure DC bus (technician): Verify that DC bus voltage is within design limits when powered.
  • 5. Replace PCB: If P0 persists and supply voltage is normal, replace the outdoor inverter PCB.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter PCB (Camry Condenser Unit)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements