P2
Camry
High Temperature Protection of Outdoor Unit
P2 displayed; unit stops during cooling and may restart after some time
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Outdoor coil blocked on Camry condenser, Outdoor fan speed too low, Unit installed in confined or poorly ventilated area, High ambient temperature exceeding design limits
How to Fix / Troubleshooting
Safety first: Turn off power before cleaning or moving obstructions.
- 1. Clean outdoor coil: Remove dirt and debris as described earlier.
- 2. Improve ventilation: Ensure adequate clearance around the outdoor unit and remove any covers or structures that trap hot air.
- 3. Check fan speed: Observe the outdoor fan; if it runs slowly or intermittently, test the motor and capacitor (if applicable).
- 4. Reduce load: In extreme heat, raise the thermostat setpoint slightly to reduce compressor load.
- 5. Technician diagnosis: If P2 persists, a technician should check refrigerant charge and outdoor PCB temperature sensing.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Outdoor Fan Motor (Camry Condenser Unit)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements