Possible Causes

Open circuit in compressor wiring harness on Camry unit, Faulty inverter IPM output stage, Loose connector between PCB and compressor, Compressor internal open circuit

How to Fix / Troubleshooting

Safety first: Isolate power before accessing outdoor wiring.

  • 1. Inspect compressor harness: Check the multi-core cable from the outdoor PCB to the compressor for damage or loose connectors.
  • 2. Tighten terminals: Ensure all compressor terminals are tight and properly insulated.
  • 3. Continuity test: A technician should verify continuity of each compressor phase from PCB to compressor.
  • 4. IPM test: If wiring and compressor are good, the inverter output stage may be faulty and the PCB should be replaced.
  • 5. Do not bypass: Never bypass inverter protections; this can cause catastrophic failure.