Carrier Reversing Valve or Control Logic Fault

Carrier air conditioner cycles between heating and cooling unexpectedly (heat pump models)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sticking reversing valve, Faulty reversing valve coil, Thermostat or control board misconfiguration, Shorted control wiring

How to Fix / Troubleshooting

Safety: Turn OFF power before accessing outdoor components.

  • Step 1 – Verify thermostat settings: Ensure the thermostat is not in AUTO-CHANGEOVER mode with a very narrow deadband that could cause frequent switching.
  • Step 2 – Observe outdoor unit: Listen for the reversing valve solenoid clicking when changing modes. Lack of sound may indicate a coil issue.
  • Step 3 – Wiring check: Have a technician inspect control wiring for shorts between O/B (reversing valve) and other terminals.
  • Step 4 – Technician service: Reversing valve diagnosis and replacement require a Carrier technician with refrigeration tools.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Reversing Valve Coil
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements