Mechanical Vibration / Loose Components
Carrier air conditioner makes loud rattling or buzzing noises during operation
Advertisements
Possible Causes
Loose fan blade or blower wheel, Loose panel screws, Debris in fan, Failing fan motor bearings
How to Fix / Troubleshooting
Safety: Turn OFF power before touching any moving parts.
- Step 1 – Identify source: Listen near the indoor and outdoor units to determine where the noise originates.
- Step 2 – Tighten panels: Check all access panels and covers for loose screws and tighten them.
- Step 3 – Inspect fans: Look for debris in the indoor blower or outdoor fan. Remove any foreign objects.
- Step 4 – Check fan blades: Ensure the outdoor fan blade is tight on the motor shaft and not bent. Straighten minor bends carefully or replace the blade.
- Step 5 – Motor bearings: If noise is a grinding or squealing sound, the motor bearings may be failing and the motor should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Outdoor Fan Blade
Check Price on Amazon