E7
Carrier Mode Conflict / Indoor-Outdoor Mismatch or Reversing Valve Error

Indoor unit displays E7 and outdoor unit does not operate

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect wiring between indoor and outdoor units, Faulty 4-way reversing valve coil, Indoor units calling for different modes on multi-split system, Control PCB logic fault

How to Fix / Troubleshooting

Safety: Turn OFF power to both indoor and outdoor units before checking wiring.

  • Step 1 – Confirm system type: If you have a multi-split Carrier system with multiple indoor units, ensure all indoor units are set to the same mode (all cooling or all heating). Mixed modes can trigger E7.
  • Step 2 – Check wiring: At both indoor and outdoor terminal blocks, verify that the control wires are correctly matched (e.g., 1–2–3 or S1–S2–S3). Correct any miswiring.
  • Step 3 – Power reset: Turn OFF the breaker for 5 minutes, then restore power and test again.
  • Step 4 – Technician diagnosis: If E7 persists, a technician should test the reversing valve coil and control PCB outputs to ensure proper mode switching.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

4-Way Reversing Valve Coil
Check Price on Amazon