Carrier Compressor Overheating / High Discharge Temperature Protection

Indoor unit shows P2 and outdoor unit stops, especially in high ambient temperatures

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coil, Outdoor fan not running or running slowly, Low refrigerant charge, Blocked airflow around outdoor unit

How to Fix / Troubleshooting

Safety: Turn OFF power at the outdoor disconnect before cleaning or servicing.

  • Step 1 – Clear obstructions: Ensure at least 2–3 feet of clearance around the outdoor unit. Remove leaves, covers, or objects blocking airflow.
  • Step 2 – Clean condenser coil: Rinse the coil with a garden hose from inside out. Avoid high pressure that can bend fins.
  • Step 3 – Check outdoor fan: Confirm the fan starts and runs at normal speed when cooling is demanded. If not, see fan motor fault procedures.
  • Step 4 – Shade and ventilation: If the unit is in direct sun or a confined space, consider adding shade or improving ventilation.
  • Step 5 – Technician service: If P2 persists, a technician should check refrigerant charge and compressor discharge temperature.