P2
Carrier
Compressor Overheating / High Discharge Temperature Protection
Indoor unit shows P2 and outdoor unit stops, especially in high ambient temperatures
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coil, Outdoor fan not running or running slowly, Low refrigerant charge, Blocked airflow around outdoor unit
How to Fix / Troubleshooting
Safety: Turn OFF power at the outdoor disconnect before cleaning or servicing.
- Step 1 – Clear obstructions: Ensure at least 2–3 feet of clearance around the outdoor unit. Remove leaves, covers, or objects blocking airflow.
- Step 2 – Clean condenser coil: Rinse the coil with a garden hose from inside out. Avoid high pressure that can bend fins.
- Step 3 – Check outdoor fan: Confirm the fan starts and runs at normal speed when cooling is demanded. If not, see fan motor fault procedures.
- Step 4 – Shade and ventilation: If the unit is in direct sun or a confined space, consider adding shade or improving ventilation.
- Step 5 – Technician service: If P2 persists, a technician should check refrigerant charge and compressor discharge temperature.