E7
Chigo
Mode Conflict / Indoor-Outdoor Mismatch or Reversed Wiring
Indoor unit shows E7 and the outdoor unit does not respond; no compressor or fan operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect indoor-outdoor wiring sequence on Chigo terminals, Mixed indoor unit types on a multi-split system, Faulty indoor PCB sending invalid mode commands, Incorrect DIP switch or address settings on indoor PCB
How to Fix / Troubleshooting
Safety first: Turn off power to the entire system before adjusting wiring or switches.
- Step 1 – Confirm model compatibility: Check that the indoor and outdoor units are designed to work together (same series and capacity range) according to Chigo documentation.
- Step 2 – Verify terminal mapping: Ensure that terminal 1 on the indoor unit goes to terminal 1 on the outdoor unit, 2 to 2, etc. Correct any cross-wiring.
- Step 3 – Check DIP switches / address settings: On some Chigo models, indoor units have address or mode DIP switches. Verify they are set according to the installation manual, especially on multi-split systems.
- Step 4 – Reset system: After corrections, power down for 5 minutes, then restart and test.
- Step 5 – PCB replacement: If E7 remains and wiring/settings are correct, the indoor main PCB may be sending invalid commands and should be tested or replaced by a technician.