F2
Chigo Outdoor Ambient Temperature Sensor Fault

Indoor unit displays F2 and may stop cooling or show abnormal defrost behavior in heat mode.

Advertisements

Possible Causes

Failed outdoor ambient NTC sensor on Chigo condenser, Broken sensor wiring, Corroded connector at outdoor PCB

How to Fix / Troubleshooting

Safety first: Turn off power at the outdoor disconnect or breaker.

  • Step 1 – Locate outdoor ambient sensor: It is usually mounted near the outdoor coil or on the control box, exposed to outside air.
  • Step 2 – Inspect wiring: Check for damage from weather or animals. Repair or replace damaged wires.
  • Step 3 – Measure sensor resistance: Disconnect the sensor from the outdoor PCB and measure resistance. Compare to the Chigo chart. Replace if readings are abnormal.
  • Step 4 – Replace sensor: Install a new outdoor ambient temperature sensor, secure it in the same location, and reconnect to the PCB.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Outdoor Ambient Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements