F8
Chigo Inverter Module Overheat / Heatsink Temperature Protection

Indoor unit displays F8 and compressor speed is limited; poor cooling or heating.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked airflow around outdoor control box, Failed outdoor fan causing poor cooling of inverter module, Dried or missing thermal paste between IPM and heatsink, Faulty heatsink temperature sensor

How to Fix / Troubleshooting

Safety first: Turn off power before opening the outdoor control box.

  • Step 1 – Ensure outdoor ventilation: Make sure the outdoor unit has adequate clearance and is not enclosed.
  • Step 2 – Check outdoor fan: Confirm the fan runs properly to cool both the coil and the control box area.
  • Step 3 – Inspect control box: Open the control box and gently remove dust from the PCB and heatsink using dry compressed air.
  • Step 4 – Technician tasks: A professional can check the heatsink temperature sensor and reapply thermal compound between the IPM and heatsink if necessary, or replace the outdoor PCB.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heatsink Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements