Coleman Continuous Operation / Control or Capacity Problem

Coleman air conditioner runs continuously and rarely shuts off, even when the set temperature is reached.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Thermostat not sensing room temperature correctly, Stuck relay on Coleman control board, Low refrigerant charge reducing capacity, Poor duct insulation or air leaks

How to Fix / Troubleshooting

Safety: Turn OFF power before removing thermostat or control board covers.

  • Check thermostat calibration: Compare thermostat reading to an accurate room thermometer. If off by several degrees, recalibrate or replace the thermostat.
  • Thermostat location: Ensure it is not in a drafty area or near heat sources that skew readings.
  • Inspect control board: Look for a stuck compressor relay on the Coleman board (contacts welded closed). Replace the board if the compressor runs even with no call for cooling.
  • Check for air leaks: Inspect ductwork for leaks in attics or crawlspaces and seal as needed.
  • Refrigerant check: If the unit cannot reach setpoint despite long run times, have a technician check refrigerant charge and system capacity.

Note: In very hot weather, long run times can be normal if the system is correctly sized.