Coleman
Short Cycling / Control or Capacity Issue
Coleman air conditioner short cycles, turning on and off frequently without reaching set temperature.
Advertisements
Possible Causes
Oversized Coleman AC unit, Thermostat located near supply vent or heat source, Dirty air filter causing freeze-thaw cycles, Low refrigerant charge
How to Fix / Troubleshooting
Safety: Turn OFF power before moving thermostat wiring or opening panels.
- Check thermostat location: Ensure the thermostat is not directly in the path of a supply vent, in direct sunlight, or near appliances that generate heat. Relocate if necessary.
- Replace filter: Install a clean air filter to prevent coil freezing.
- Observe operation: Watch the indoor coil for signs of icing during operation. If ice forms, address airflow and have a technician check refrigerant charge.
- Adjust thermostat settings: Increase the temperature differential or cycle rate if your thermostat allows, to reduce short cycling.
Note: If the unit is significantly oversized for the space, only equipment replacement or zoning will fully resolve short cycling.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements