F3
Coleman
Indoor Fan Motor / Fan Feedback Fault
Coleman RV rooftop air conditioner shows F3 and the fan may not operate correctly or at all.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed indoor blower motor in Coleman-Mach unit, Seized fan wheel, Open fan capacitor, Loose fan motor wiring
How to Fix / Troubleshooting
Safety: Disconnect 120V power to the RV and verify power is off before touching the fan or motor wiring.
- Check fan movement: With power OFF, spin the indoor blower wheel by hand. It should rotate freely. If stiff or seized, the motor bearings may be failing or debris is lodged in the wheel.
- Inspect capacitor: Locate the fan or dual run capacitor in the rooftop unit’s electrical box. Discharge it safely, then test capacitance. Replace if out of spec.
- Verify wiring: Ensure all fan motor leads are securely connected to the Coleman-Mach control board and capacitor terminals. Look for burnt or discolored connectors.
- Test operation: Restore power and call for fan-only mode. If the fan still does not run or F3 returns, the motor is likely defective.
- Replace fan motor: Remove the blower housing and motor assembly per Coleman-Mach service instructions. Install a compatible replacement motor and reassemble.
Note: Mark wire positions and take photos before removing the old motor to ensure correct reconnection.