H3
Coleman Defrost Cycle Failure / Excessive Frost on Outdoor Coil

Coleman heat pump air conditioner shows H3 and may shut down heating operation during cold weather.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed defrost control board, Defective outdoor coil sensor, Stuck reversing valve, Outdoor fan not running during heat mode

How to Fix / Troubleshooting

Safety: Turn OFF power at the outdoor disconnect before servicing the condenser.

  • Visual inspection: Check the outdoor coil for heavy frost or ice buildup. If the coil is encased in ice, the defrost cycle is not working properly.
  • Check outdoor fan: In heat mode, confirm the outdoor fan runs. If not, troubleshoot the fan motor and capacitor as previously described.
  • Verify coil sensor: Inspect and test the outdoor coil sensor as in H2. Replace if defective.
  • Defrost board check: Inspect the defrost control board for burnt components or water damage. Ensure all connectors are seated.
  • Reversing valve operation: Listen for the reversing valve shifting when switching between heat and cool. If it does not shift and wiring is correct, the valve or coil may be faulty.
  • Professional service: If H3 persists after sensor and fan checks, a technician should test the defrost board logic and reversing valve operation.

Note: Do not attempt to manually chip ice off the coil; allow it to melt naturally or use warm air.