Comfortmaker
Short Cycling / Improper Capacity Control
Comfortmaker air conditioner short cycles; turns on and off frequently without reaching set temperature
Advertisements
Possible Causes
Oversized system, Thermostat located near supply register or heat source, Dirty filter or coil causing freeze-thaw cycles, Low refrigerant charge
How to Fix / Troubleshooting
Safety: Turn off power before moving thermostat wires or opening panels.
Steps:
- Check thermostat location: Ensure it is not directly in airflow from a supply register or in direct sunlight. Relocate if necessary.
- Replace filter and clean coils: Improve airflow to prevent freeze-ups.
- Observe operation: Watch for icing on the suction line or evaporator. If present, turn system off to thaw and call a technician.
- Adjust thermostat settings: Increase cycle rate or differential if available in thermostat menu.
Note: Persistent short cycling may indicate sizing or refrigerant issues that require professional evaluation.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements