Possible Causes

Oversized system, Thermostat located near supply register or heat source, Dirty filter or coil causing freeze-thaw cycles, Low refrigerant charge

How to Fix / Troubleshooting

Safety: Turn off power before moving thermostat wires or opening panels.

Steps:

  • Check thermostat location: Ensure it is not directly in airflow from a supply register or in direct sunlight. Relocate if necessary.
  • Replace filter and clean coils: Improve airflow to prevent freeze-ups.
  • Observe operation: Watch for icing on the suction line or evaporator. If present, turn system off to thaw and call a technician.
  • Adjust thermostat settings: Increase cycle rate or differential if available in thermostat menu.

Note: Persistent short cycling may indicate sizing or refrigerant issues that require professional evaluation.