Comfortmaker
Compressor Not Starting
Comfortmaker outdoor fan runs but compressor does not; no cooling
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor section of dual run capacitor, Open compressor winding, Internal compressor overload open, Faulty contactor pole feeding compressor
How to Fix / Troubleshooting
Safety: Disconnect power at the outdoor disconnect before testing.
Steps:
- Test dual run capacitor: Focus on the HERM (compressor) terminal. Replace capacitor if out of spec.
- Inspect wiring: Ensure all compressor leads are firmly attached and not burned.
- Check contactor: Verify both poles are delivering voltage when energized.
- Allow cool-down: If compressor is very hot, let it cool for 1–2 hours and retry.
Technician required: If compressor windings test open/shorted or still will not start, compressor replacement may be needed.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Dual Run Capacitor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements