F5
Comfortmaker Defrost Sensor / Coil Sensor Fault

Display shows F5 and unit may not defrost properly (heat pump models) or may shut down

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor defrost thermistor, Sensor not properly attached to coil, Damaged wiring, Defective defrost control on outdoor PCB

How to Fix / Troubleshooting

Safety: Turn off power to the heat pump at the disconnect.

Steps:

  • Locate defrost sensor: Typically clipped to the outdoor coil tubing on Comfortmaker heat pumps.
  • Check attachment and position: Ensure firm contact with coil and not hanging loose.
  • Inspect wiring and connector: Repair any damaged wires and reseat connector on PCB.
  • Test resistance: Compare sensor resistance to the thermistor chart. Replace if out of range.

Note: If sensor is good but F5 persists, the defrost control function on the outdoor board may be faulty.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost Temperature Sensor
Check Price on Amazon