A6
Daikin
Indoor Fan Motor Fault
Indoor fan does not run or stops; A6 error appears on Daikin controller
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed indoor DC fan motor, Jammed blower wheel, Faulty fan motor drive circuit on indoor PCB, Loose fan motor connector
How to Fix / Troubleshooting
Safety first: Disconnect power before removing the indoor unit cover or touching the fan.
Steps:
- Remove the front panel and filters to access the blower area.
- Check if the blower wheel spins freely by hand; remove any foreign objects or heavy dust buildup.
- Inspect the fan motor wiring harness and connector; reseat firmly.
Technician actions:
- Measure fan motor supply voltage from the PCB when the unit calls for fan operation.
- If voltage is present but the motor does not run, replace the indoor fan motor.
- If no voltage is present and the motor is good, replace or repair the indoor PCB fan drive circuit.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Indoor Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements