Daikin Indoor Heat Exchanger Thermistor Fault

Indoor unit stops; C4 error displayed; may be associated with coil temperature sensing

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted indoor coil thermistor, Disconnected thermistor plug, Damaged thermistor wiring, Corroded thermistor connection

How to Fix / Troubleshooting

Safety first: Turn off power before removing covers or touching sensors.

Steps:

  • Locate the indoor heat exchanger thermistor clipped to the coil (usually a small bead sensor with two wires).
  • Ensure the sensor is firmly attached to the coil and the connector is fully seated on the PCB.

Technician actions:

  • Measure thermistor resistance at room temperature and compare with Daikin specifications.
  • Replace the thermistor if open, shorted, or out of range.
  • Inspect and repair any damaged wiring between the thermistor and PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Heat Exchanger Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements