C9
Daikin
Indoor Room Thermistor Fault
Daikin indoor unit shows C9; poor temperature control or unit stops
Advertisements
Possible Causes
Open or shorted room temperature sensor, Disconnected sensor plug, Sensor displaced from correct location, Damaged sensor wiring
How to Fix / Troubleshooting
Safety first: Turn off power before removing the front panel.
Steps:
- Locate the room thermistor near the air intake grille; ensure it is not hanging loose or touching cold surfaces.
- Check that the sensor connector is firmly attached to the PCB.
Technician actions:
- Measure resistance of the room thermistor and compare with Daikin's temperature-resistance chart.
- Replace the room thermistor if out of specification or physically damaged.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Temperature Thermistor
Check Price on Amazon
We may earn a commission from links on this page.