E1
Daikin Outdoor PCB or Power Module Failure

Outdoor unit does not start; E1 error logged on Daikin controller

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted inverter power module (IPM), Burnt components on outdoor PCB, Overcurrent event from compressor, Loose power connections

How to Fix / Troubleshooting

Safety first: This involves high voltage and high current components. Only qualified technicians should open the outdoor unit.

Technician overview:

  • Inspect the outdoor PCB and IPM for burn marks or cracks.
  • Check compressor winding resistance and insulation to ground.
  • Verify line voltage and phase (for 3-phase units).
  • Replace the outdoor PCB/IPM assembly if defective, following Daikin procedures.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter PCB / IPM Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements