E7
Daikin Four-Way Valve (Reversing Valve) Malfunction

Reversing valve does not switch between heating and cooling; E7 error logged

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed reversing valve coil, Stuck valve slide, Incorrect wiring to valve coil, Faulty outdoor PCB output

How to Fix / Troubleshooting

Safety first: Power off the unit before accessing the reversing valve coil. Refrigerant circuit must not be opened without proper equipment and certification.

Technician steps:

  • Check coil resistance and continuity; replace the coil if open.
  • Verify that the coil is receiving the correct voltage when switching modes.
  • If the coil energizes but the valve does not shift (no change in pressures or line temperatures), the valve may be mechanically stuck and require replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Reversing Valve Coil / Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements