P4
Daikin
Inverter Heat Sink Overheat
Daikin unit shows P4; compressor may not run or may stop
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked outdoor unit ventilation, Failed outdoor fan, Deteriorated thermal grease on IPM, High ambient temperature
How to Fix / Troubleshooting
Safety first: Turn off power before cleaning or servicing the outdoor unit.
User steps:
- Ensure the outdoor unit is not enclosed and has proper airflow.
- Clean the outdoor coil and surrounding area.
Technician tasks:
- Check outdoor fan operation.
- Inspect the inverter heat sink and cooling path; replace IPM or reapply thermal compound if required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Outdoor Inverter Module / Heat Sink
Check Price on Amazon
We may earn a commission from links on this page.