U4
Daikin Indoor–Outdoor Communication Failure

Indoor unit operates briefly then stops; remote shows communication error; some Daikin systems display U4 on wired controller

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or short in communication wiring between indoor and outdoor units, Reversed polarity on S1/S2/S3 or A/B terminals, Loose terminal screws at indoor or outdoor PCB, Faulty indoor or outdoor main PCB communication circuit

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker before touching any wiring or opening covers.

Steps to check:

  • Locate the communication cable between indoor and outdoor units (often labeled S1/S2/S3 or 1/2/3 on Daikin split systems).
  • Verify that the same terminal numbers are connected between indoor and outdoor units (e.g., S1 to S1, S2 to S2, S3 to S3). Correct any miswiring.
  • Check that all terminal screws are tight and that no copper conductor is exposed or touching adjacent terminals.
  • Inspect the cable for cuts, rodent damage, or crushed sections along its route.

Advanced/technician actions:

  • Measure continuity of each communication core from indoor to outdoor; repair or replace the cable if open or shorted.
  • Check for correct polarity on any 2-wire communication bus (A/B) if used; reverse if incorrectly wired.
  • If wiring is sound, test by substituting a known-good indoor or outdoor PCB (as per Daikin service manual) to identify a faulty board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Indoor–Outdoor Communication Cable
Check Price on Amazon