E5
Danby Compressor Overload / Overcurrent Protection or Voltage Error (Model-Dependent)

Display shows E5 and the compressor does not start or shuts down quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low supply voltage or unstable power, Shorted compressor winding, Failing compressor start capacitor or PTC relay, Faulty main control board power stage

How to Fix / Troubleshooting

Safety: Unplug the unit. The compressor circuit carries high current; only proceed if you are comfortable working with electrical components.

Steps:

  • 1. Verify power supply: Use a plug-in voltage tester or multimeter to confirm the outlet provides stable voltage within the range specified on the Danby nameplate (typically 115V or 230V). Avoid using long undersized extension cords.
  • 2. Inspect wiring: Remove the rear cover to access the compressor compartment. Check for burnt wires, loose spade connectors, or melted insulation at the compressor terminals and capacitor.
  • 3. Check start components: Locate the compressor start capacitor and PTC relay (if used). Look for bulging, leaking, or cracked capacitors. Replace with a Danby-specified capacitor of the same µF rating and voltage.
  • 4. Test compressor windings: With the unit unplugged and capacitor discharged, remove the compressor terminal cover. Using a multimeter, measure resistance between the three terminals (C, S, R). None should be open or shorted to ground. If windings are shorted or open, the compressor is defective.
  • 5. Inspect main PCB: Look for burnt components or darkened areas near the compressor relay or triac. If damaged, replace the main control board.
  • 6. Reassemble and test: After replacing any faulty parts, reassemble, restore power, and test operation. If E5 persists with correct voltage and new start components, professional compressor diagnosis is recommended.
Advertisements

Repair Difficulty

Professional Required 5/5