F4
Danby Indoor Fan Motor Error / Feedback Fault

Display shows F4, unit may not respond to commands or may shut down unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Fan motor not starting, Blocked blower wheel, Failed fan motor Hall sensor, Loose fan connector, Faulty PCB fan driver

How to Fix / Troubleshooting

Safety: Disconnect power before working near moving parts.

Steps:

  • 1. Check for obstructions: Remove the front grille and filter. Inspect the blower wheel for foreign objects and remove any debris.
  • 2. Manual spin: Spin the blower by hand. If it binds or grinds, the motor or bearings are failing and should be replaced.
  • 3. Inspect wiring: Verify the fan motor connector is fully seated on the PCB and wires are intact.
  • 4. Test motor (advanced): With power applied and a fan command active, measure the supply to the motor per service data. If voltage is present but the motor does not run, replace the motor. If no voltage, suspect the PCB.
  • 5. Replace components: Install a new Danby indoor fan motor or main PCB as indicated by testing.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Indoor Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements