HI
Danby
High Ambient Temperature Indication / Sensor Reading Above Range
Display shows HI and unit may run continuously or shut down on protection.
Advertisements
Possible Causes
Room temperature above design range, Direct sunlight heating the sensor area, Faulty ambient thermistor reading too high
How to Fix / Troubleshooting
Steps:
- 1. Verify ambient temperature: Use a thermometer to check room temperature. If extremely hot, improve shading and ventilation.
- 2. Reduce heat load: Close blinds, reduce internal heat sources, and ensure doors/windows are closed.
- 3. Sensor check: If HI appears in a moderate room, inspect the ambient sensor for loose mounting or damage and test resistance. Replace if out of spec.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Thermistor (Room Temperature Sensor)
Check Price on Amazon