Danby
Short Cycling / Incorrect Temperature Sensing
Unit cools briefly then shuts off compressor, cycling on and off frequently.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Ambient thermistor located too close to cold discharge, Dirty filter causing coil freeze, Oversized unit for small room, Faulty thermistor or control board
How to Fix / Troubleshooting
Steps:
- 1. Verify installation: Ensure the unit is sized appropriately for the room. An oversized unit will short cycle.
- 2. Clean filter and coil: Restricted airflow can cause the evaporator to freeze and trigger protection. Clean the filter and evaporator coil thoroughly.
- 3. Check sensor location: Locate the ambient thermistor and ensure it is near the air intake, not directly in the cold air stream. Reposition if necessary using clips or tape.
- 4. Test sensor: Measure thermistor resistance and compare to expected values. Replace if readings are unstable or out of range.
- 5. Control board: If sensor is good and placement correct, but short cycling persists, the main PCB thermostat logic may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient Thermistor (Room Temperature Sensor)
Check Price on Amazon
We may earn a commission from links on this page.