E6
Day & Night Outdoor Unit EEPROM/PCB Fault

E6 on display, indoor fan may run but no cooling, intermittent operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor control board, Corrupted EEPROM on outdoor PCB, Voltage surge damage to electronics, Loose board connectors

How to Fix / Troubleshooting

Safety first: Turn OFF the outdoor disconnect and indoor breaker before servicing. Electronic boards are static-sensitive.

  • Step 1 – Power reset: Leave power OFF to both indoor and outdoor units for at least 5 minutes, then restore. Sometimes an EEPROM error will clear after a full reset.
  • Step 2 – Inspect outdoor PCB: Remove the condenser service panel. Check the control board for burn marks, insect nests, or moisture damage. Ensure all multi-pin connectors are fully seated.
  • Step 3 – Check cabinet sealing: Confirm the control compartment cover gasket is intact to prevent future moisture intrusion.
  • Step 4 – Surge protection: If E6 followed a storm or power event, consider installing a surge protector on the condensing unit (by a professional) after board replacement.
  • When to call a pro: EEPROM/PCB faults almost always require board replacement and configuration by a Day & Night–qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Control Board (Condenser PCB)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements