E8
Day & Night Indoor Fan Motor Overload / Overheat Protection

E8 displayed, unit shuts down after running, may restart after a while

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty or clogged air filter, Blocked supply or return vents, Failing indoor blower motor (PSC or ECM), Seized blower wheel, Faulty indoor fan speed control on PCB

How to Fix / Troubleshooting

Safety first: Turn OFF power at the indoor unit disconnect and breaker before working on the blower.

  • Step 1 – Replace or clean filter: Remove the return air filter and replace with a clean filter of the correct size and MERV rating recommended by Day & Night. A severely clogged filter can overheat the motor.
  • Step 2 – Check airflow: Ensure all supply registers and return grilles are open and not blocked by furniture or rugs.
  • Step 3 – Inspect blower wheel: Remove the blower access panel. Check that the blower wheel spins freely by hand and is not packed with dust or debris. Clean carefully if dirty.
  • Step 4 – Motor condition: Look for signs of overheating (burnt smell, discoloration) on the blower motor. If the motor is very hot to the touch or noisy, it may be failing and should be replaced.
  • Step 5 – ECM diagnostics: On ECM motors, check the low-voltage harness to the motor module. Loose connections can cause overcurrent trips.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Blower Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.