H0
Day & Night Low Voltage / Power Supply Fault

H0 code, unit does not start, display may be blank or show only H0

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown low-voltage fuse on indoor control board, Tripped breaker or open disconnect, Failed 24V transformer in air handler, Loose line-voltage connections

How to Fix / Troubleshooting

Safety first: Turn OFF all breakers before removing access panels. Use a multimeter only if you are trained to work with live circuits.

  • Step 1 – Check breakers: Verify the indoor air handler/furnace breaker and outdoor condenser breaker are ON. Reset if tripped once; repeated tripping indicates a fault.
  • Step 2 – Inspect low-voltage fuse: On the indoor control board, locate the 3–5A blade fuse protecting the 24V circuit. If blown, replace with the same rating. If it blows again, there is a short in the thermostat or control wiring.
  • Step 3 – Transformer check: Listen for a slight hum from the 24V transformer. If there is no 24V between R and C at the board (tested by a qualified person), the transformer may be failed.
  • Step 4 – Wiring inspection: Look for loose or burnt wires at the line-voltage terminal block and disconnects.
  • Call a professional: Persistent H0 or repeated fuse blowing requires a technician to locate shorts and verify safe operation.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

24V Control Transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements