Day & Night Thermostat or Control Signal Failure

Indoor unit blows warm air in cooling mode; outdoor unit not running

Advertisements

Possible Causes

Thermostat not sending Y call, Broken thermostat wire between thermostat and air handler, Blown 24V fuse on indoor board, Misconfigured thermostat mode

How to Fix / Troubleshooting

Safety first: Turn OFF power to the indoor unit before removing thermostat or access panels.

  • Step 1 – Thermostat settings: Confirm thermostat is set to COOL and temperature is below room temperature. Ensure system is not in FAN ONLY mode.
  • Step 2 – Check batteries: Replace thermostat batteries if applicable.
  • Step 3 – Inspect wiring at thermostat: Remove thermostat and verify wires are firmly attached to R, C (if used), Y, G, and O/B (heat pump) as appropriate.
  • Step 4 – Indoor board fuse: Check the low-voltage fuse on the indoor control board and replace if blown.
  • Step 5 – Bypass test (qualified persons only): Temporarily jumper R to Y and G at the indoor board to see if the outdoor unit and blower start. If they do, the thermostat or its wiring is faulty.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Wall Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements