Day & Night No Power to Indoor Unit

Indoor unit does not start at all; no blower, no display, thermostat blank

Advertisements

Possible Causes

Tripped indoor breaker, Blown internal fuse, Failed door safety switch, Loose line-voltage connection at air handler

How to Fix / Troubleshooting

Safety first: Use caution around electrical panels. Turn OFF main power if necessary.

  • Step 1 – Check breaker: Verify the air handler/furnace breaker is ON. Reset once if tripped.
  • Step 2 – Door switch: Ensure the blower door is properly closed and engaging the safety switch.
  • Step 3 – Internal fuses: Some Day & Night air handlers have internal line fuses. Inspect and replace only with identical type and rating.
  • Step 4 – Terminal block: Check that incoming power wires are tight at the indoor unit terminal block.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Safety Switch or Internal Line Fuse
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements