Day & Night Mechanical Vibration / Fan or Mounting Issue

Loud banging or rattling noise from outdoor unit during operation

Advertisements

Possible Causes

Loose outdoor fan blade, Debris caught in fan, Loose compressor mounting bolts, Cabinet panels not secured

How to Fix / Troubleshooting

Safety first: Turn OFF power at the outdoor disconnect before inspecting the unit.

  • Step 1 – Inspect fan blade: Look through the top grille for bent blades or foreign objects. Remove any debris.
  • Step 2 – Check blade tightness: Remove the top panel and verify the fan blade set screw is tight on the motor shaft.
  • Step 3 – Tighten panels: Ensure all cabinet screws are tight and panels are not vibrating.
  • Step 4 – Compressor mounts: Check that compressor mounting bolts and rubber isolators are intact. Replace damaged isolators.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Outdoor Fan Blade
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements