Day & Night Ductwork Imbalance / Air Distribution Issue

Uneven cooling in different rooms; some rooms too hot, others too cold

Advertisements

Possible Causes

Closed or partially closed dampers, Crushed or disconnected flex duct, Poorly designed duct layout, Dirty or restrictive filters at room grilles

How to Fix / Troubleshooting

Safety first: Use caution in attics or crawlspaces when inspecting ducts.

  • Step 1 – Check registers and dampers: Ensure all supply and return registers are open. Adjust balancing dampers if present.
  • Step 2 – Inspect accessible ducts: Look for disconnected or crushed ducts, especially near the air handler.
  • Step 3 – Remove grille filters: If individual room filters are installed at grilles, clean or remove them if overly restrictive.
  • Step 4 – Professional balancing: For persistent issues, have a contractor perform duct balancing and possibly add returns.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Supply and Return Ductwork
Check Price on Amazon