E7
De'Longhi Mode Conflict / Reversing Valve or Control Logic Error

Display shows E7 and the unit may not respond to mode changes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck reversing valve (heat pump models), Faulty mode relay on main PCB, Incorrect mode command from control panel, Wiring fault to reversing valve coil

How to Fix / Troubleshooting

Safety first: Turn off and unplug the unit before accessing internal components.

  • 1. Reset control: Turn the unit OFF, unplug for 10 minutes, then plug back in and try selecting a different mode (e.g., FAN, then COOL).
  • 2. Listen for valve operation: On heat pump models, you should hear a click or slight whoosh when switching between COOL and HEAT. If there is no sound, the reversing valve coil may not be energized.
  • 3. Inspect wiring: Access the main PCB and locate the wires going to the reversing valve coil. Check for loose connectors or damaged wires.
  • 4. Control panel check: Ensure buttons are not stuck and the remote (if used) has fresh batteries and is sending correct commands.
  • 5. Technician service: If E7 persists, a technician should test the reversing valve coil resistance and the PCB output. Replacement of the valve or PCB may be required.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Reversing Valve Coil
Check Price on Amazon