Ft
De'Longhi Frost Protection / Defrost Mode Indication

Display shows Ft and the unit stops; often associated with frost or ice on the coil.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator coil temperature below safe limit, Low airflow due to dirty filter, Low refrigerant charge, Very low ambient temperature

How to Fix / Troubleshooting

Safety first: Turn off and unplug the unit before inspecting for ice.

  • 1. Inspect for ice: Remove the front panel and look at the evaporator coil. If covered in ice, leave the unit off until all ice melts.
  • 2. Clean filters: Wash and dry the air filters to restore airflow.
  • 3. Check fan speed: Run the unit in FAN mode and verify strong airflow. Weak airflow may indicate a failing fan motor.
  • 4. Adjust settings: Increase the set temperature slightly and avoid running on maximum cooling continuously in small rooms.
  • 5. Technician evaluation: If Ft recurs frequently, a technician should check refrigerant charge and sensor calibration.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements