E6
Electrolux Indoor-Outdoor Communication Error / Mismatched Units

Indoor unit shows E6, outdoor unit does not respond or runs erratically

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged communication cable, Incorrect wiring between indoor and outdoor terminals, Mismatched indoor and outdoor model pairing, Faulty indoor PCB, Faulty outdoor PCB

How to Fix / Troubleshooting

Safety: Turn off the main breaker before opening any covers.

Steps:

  • Confirm model compatibility: Check that the indoor and outdoor units are designed to work together (same series and capacity as per Electrolux documentation).
  • Verify wiring: Open the indoor and outdoor electrical covers. Confirm that terminal labels (e.g., 1-2-3 or L-N-S) are wired identically and securely. Tighten any loose screws.
  • Inspect cable: Look for physical damage along the interconnecting cable. Replace if there are cuts, burns, or crushed sections.
  • Check grounding: Ensure proper earth/ground connection at both units. Poor grounding can cause communication noise.
  • Power cycle: After corrections, turn power back on and test. If E6 persists, the communication circuits on either PCB may be defective.

Board-level diagnosis and replacement should be performed by an authorized technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Indoor Main PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements