F2
Electrolux Evaporator Sensor Out of Range

Display shows F2, unit may stop during cooling

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aged or damaged evaporator NTC, Sensor not in good thermal contact with coil, Corroded connector, Faulty indoor PCB

How to Fix / Troubleshooting

Safety: Disconnect power.

Steps:

  • Check sensor mounting: Ensure the evaporator sensor is firmly clipped to the coil and not hanging loose.
  • Inspect for corrosion: Clean any oxidation on the connector with contact cleaner and reseat.
  • Replace sensor: Install a new evaporator temperature sensor if F2 recurs.
  • Board check: If a new sensor does not fix F2, the indoor PCB sensor circuit may require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Temperature Sensor (NTC)
Check Price on Amazon