Possible Causes
Oversized unit for room, Thermostat sensor too close to supply air, Dirty filters causing icing, Low refrigerant charge, Faulty control board
How to Fix / Troubleshooting
Safety: Turn off power before moving sensors.
Steps:
- Check sensor location: Ensure the room temperature sensor is in the return air stream, not directly in the cold supply air.
- Clean filters and coils: Dirty components can cause icing and short cycling.
- Check setpoint: Avoid setting the temperature extremely low; set around 23–25°C for normal cooling.
- Observe cycle time: If the unit cycles every few minutes even under moderate load, a technician should check refrigerant charge and control logic.