Fraser-Johnston Overcurrent / Short Circuit Condition

Breaker trips when air conditioner starts or shortly after

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted compressor, Shorted condenser fan motor, Shorted wiring to ground, Oversized or weak breaker

How to Fix / Troubleshooting

Safety: Do not repeatedly reset a tripping breaker. Risk of fire or equipment damage.

  • Visual inspection: With power off, inspect wiring in both indoor and outdoor units for burnt insulation or contact with sharp metal edges.
  • Isolate loads: A technician can disconnect compressor and fan leads to test each component individually for shorts to ground.
  • Check breaker size: Confirm breaker size matches Fraser‑Johnston unit nameplate MCA/MOP ratings.
  • Replace failed components: Replace any motor or compressor found shorted, or replace the entire condenser if compressor is failed.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements