Fraser-Johnston Compressor Start Failure

Outdoor fan runs but compressor does not start

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed run capacitor, Open compressor winding, Failed compressor contactor, Loose compressor wiring terminals

How to Fix / Troubleshooting

Safety: Turn off power at the disconnect and verify with a meter before touching components.

  • Inspect capacitor: Locate the dual run capacitor in the condenser. If bulged or leaking, replace with the same µF and voltage rating.
  • Check wiring: Ensure all compressor terminals (C, R, S) are firmly connected and not burnt.
  • Test contactor: Confirm the contactor contacts are not pitted or burned. Replace if they are not making good contact.
  • Measure compressor resistance: With wires removed and power off, measure resistance between compressor terminals and to ground. A short to ground or open winding indicates a failed compressor.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Dual Run Capacitor
Check Price on Amazon

We may earn a commission from links on this page.